![]() Package Boilers Commercial and Marine
|
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |

|
|
| Compact
Cyclotherm occupies
up to two thirds LESS space than conventional steam generators because
of its simple 2 pass, Scotch Marine type construction. Cyclonic
Combustion
transfers at least 65% of the heat energy in the fuel directly through
the fire tube, and an additional 15% in the single return pass.
Conventional
steam generators add only extra weight and bulk but get no more
efficiency. During World War II, the U.S. Navy requested Cyclotherm's engineers to develop a compact, lightweight, steam generator which would develop top efficiency under the most rugged operating conditions. Patented Cyclonic Combustion answered these demands so well that Cyclotherm has become the leader in supplying auxiliary boilers for shipboard use. No other steam generator can match the Cyclotherm for operating efficiency, trouble free service, long life, and maximum of performance in a minimum of space. |
![]() |
![]() |
![]() |
| Water treatment tanks are mounted on side and piped to feedwater pump systems. By-pass piping permits manually controlled water circulation | An oil pump set assembly is furnished and placed under the unit, to save you space and eliminate connecting and installing on the job. | Electronic control panel is easily accessible for checking and adjusting. Provides automatic operations. Mounted on side of boiler at eye level. |
![]() |
![]() |
![]() |
| A flanged air intake is provided on the Cyclotherm Marine Steam Generator in order to connect the unit's ductwork to the weather outside. | The modulation sequence has been developed further to provide a wider range of modulation to meets the demands and rigors of marine use. | The Cyclotherm Steam Generator is provided with a flanged flue uptake. This uptake connects the stack of the unit to the weather. |
|
|
||
|
|
|
| Marine Boiler Specifications |
||||||||
| Model |
MC800 |
MC1200 |
MC1500 |
MC2500 |
MC4000 |
MC5000 |
MC7500 |
MC9000 |
| Overall Height |
4'8" |
4'6" |
5'10" |
6'6" |
7' |
7'10" |
8'7" |
8'7" |
| Overall
Width |
3'6" |
3'6" |
4' |
4'8" |
5'3" |
6' |
6'5" |
6'5" |
| Overall Length |
6' |
6' |
6'6" |
8' |
8'6" |
8'6" |
12'5" |
12'5" |
| Dry Weight, Lbs. |
2,200 |
3,500 |
5,600 |
7,500 |
11,700 |
12,500 |
18,000 |
18,000 |
| Wet Weight, Lbs. |
2,900 |
4,400 |
8,100 |
10,000 |
15,300 |
16,400 |
24,500 |
24,500 |
| *Lbs. of Steam Per Hr. Normal |
800 |
1,200 |
1,500 |
2,500 |
4,000 |
5,000 |
7,500 |
9,000 |
| *Lbs of Steam Per
Hr. Max. |
800 |
1,440 |
1,800 |
3,000 |
4,800 |
6,000 |
7,500 |
9,000 |
| Pressure, PSIG |
100, 125 150, and 200 On All Models |
|||||||
| Fuel |
Diesel On All Models |
|||||||
| Ignition |
10,000 Volt Direct |
|||||||
| Burner Operation |
On-Offf |
Modulating Through
Wide Range |
||||||
| Draft |
Forced On All Models |
|||||||
| Burner Nozzle, Cap. |
Fixed |
Variable |
||||||
| * From and at 100
Degree Water at 100 PSI |
||||||||

![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |